icon-green-circles

Air Therapy Surface with Smartimmerse Technology

PressureGuard® APM-i

At the touch of a button, proprietary electronics assist at configuring the inflation profile. The embedded algorithm helps establish appropriate air settings to promote immersion, support, and redistribution- designed to complement caregiver assessment and clinical decision-making.

  • Intelligent sensing auto-calibrates air system to each user
  • Uniquely engineered surface designed to maximize immersion and envelopment
  • Outstanding comfort optimizes rest and recovery

Benefits

icon
Simplicity

Easy to set up and operate. SmartImmerse™ Technology automatically helps customize air settings for each user, supporting an optimized balance of immersion, support, and redistribution.

icon
Safety & Comfort

Designed for support, stability, and comfort. Proven PressureGuard® design, Safety Edge bolsters, Geo-Matt® surface, and Shear Transfer Zones™ help enhance comfort, reduce shear, and support safer transfers.

icon
Pressure Redistribution

Designed to help protect vulnerable tissue. Enhanced immersion, envelopment, and redistribution help support prevention and treatment of pressure injuries.

Digital Control Unit with SmartImmerse™ Technology

Proprietary SmartImmerse™ technology within the powered control unit automatically customizes the inflation profile for each user by calculating the precise air settings required to deliver an optimized balance of immersion, support, and redistribution to complement the input of a caregiver.

  • Powered immersion mode
  • Timed (20-minute) Auto Firm mode
  • Comfort level adjustment for desired level of firmness
  • Low pressure indicator, power failure indicator and audible alarm
  • Lockout mode
Savaria PressureGuard APM i Pump

SmartImmerse™ Technology

At the touch of a button, proprietary electronics assist in configuring the inflation profile. The embedded algorithm helps establish ideal air settings to maximize immersion, support, and redistribution. Feature is designed to complement caregiver assessment and clinical decision making.

Savaria PressureGuard APM i SmartImmerse Technology

Treatment Flexibility

  • Immersion: All four cylinders are equally inflated, providing maximum immersion and envelopment.
  • Alternating Pressure: Gently changes loading across the surface (10-minute cycle).
  • Lateral Rotation: A versatile modality indicated for a variety of needs (10-minute cycle).
PG APM i Treatment Flexibility

Proven PressureGuard® Design

  • Head-to-foot air cylinder orientation optimizes pressure redistribution
  • Better support in seat area when head of bed is raised
  • Geo-Matt® segmented top surface enhances skin and tissue integrity
  • Air and foam work together to maximize comfort, promoting better rest and recovery
APM i Illustration

Safety Edge™ Design

  • Helps minimize the risk of falls and bed entrapment
  • Unmatched edge-of-bed stability
  • Helps ensure safer transfers for patients and caregivers
  • Gently encourages user toward center of bed
Safety Edge Seating Up

Unique Geo-Matt® Design

  • Segmented top layer reduces shear to underlying tissues
  • More than 800 individually-articulating cells
  • Redistributes pressure, reduces heat and skin moisture buildup

Shear Transfer Zone® Cover Design

Beyond its Geo-Matt® segmented top surface, an additional measure of shearing protection is provided by the silicone-coated, shear minimizing fabric bands located on the underside of its bi-directional stretch cover. This Shear Transfer Zone design helps:

  • Prevent heels, sacrum, and scapula from “digging into” surface
  • Glide” user back to original position following HOB elevation
  • Protect against damaging effects of micro shear, macro shear, and rotational (pivot-induced) shear
  • Provide patient stability by transferring shear to more shear-tolerant anchor points

Product Details

Downloadable Content

Owner’s Manual (PDF)
Air Therapy Surfaces Matrix (PDF)
Support Surface Algorithm and Selection Guide (PDF)
Indications for Use
  • Aggressive treatment (through Stage 4)
  • Prevention of pressure injuries in immobile or high-risk patients
  • Can’t or won’t reposition frequently
  • Can be positioned off the pressure injury
Product Codes

38036

PG APM-i 80x36 with 6200 control unit

38436

PG APM-i 84x36 with 6200 control unit

38042

PG APM-i 80x42 with 6200 control unit

38442

PG APM-i 84x42 with 6200 control unit

6200

Control Unit Only
Surface Specifications

Weight Limit

350 lbs (158.8 kg)

Mattress Weight

approx. 20 lbs (9.1 kg)

Flammability

Conforms to NFPA 101 (Life Safety Code); Cal. TB 117; ASTM E1590; and 16 CFR Parts 1632 and 1633.

Cover

Premium LifeSpanTM coated stretch fabric with Shear Transfer Zones® design
Control Unit Specifications

Weight

6.3 lbs

Voltage

120 AC

Frequency

60 Hertz

Dimensions

12” x 7.5” x 5”

Max Current

1 Amp

UL Listing

Certifed to IEC 60601-1-1
Warranty

Mattress

3 Years

Cover

2 Years

Control Unit

18 Months

Get a Quote